Current Interrupter

Current Interrupters need to turn ON and OFF the Rectifiers for cathodic protection test. Measurement ON and OFF potential shows a good explanation of the level of pipeline protection. We manufacture different ranges of GPS Current Interrupters. They are “15, 35, 50, 100, 200, and 300” AMP AC or DC with 600 volts.

 
Send Email

Hexlogger

Sophisticated survey (CIPS, DCVG, CIPS+ DCVG) , and local Data logger instrument equipped with a GPS engine that can accurately measure the Rectifier ON and OFF potential at each reading stamped with GPS coordinates, distance, UTC time. Beside its logging features, it is powerful and an accurate equipment for detecting and tracking the escaping currents of pipelines by using its barcode display option in DCVG mode.

 
Send Email

G.P.S Pipeline Current Mapper

The GPS Pipeline Current Mapper “GPCM” measures the distribution of an impressed test current on a Pipeline network. By measuring the pipeline Magnetic field, it’s able to measure pipeline current flow. It is an accurate method of mapping and evaluating the loss of cathodic protection current. The GPCM measures the current magnitude and direction without any connection. Interrupter creates the easiest method to change the CP potential to a transmitter signal. This is a Pipeline interruption locator and locates the pipeline by using the LCD Bar graph. GPCM Data logger flash memory is 2000 Mb. USB interface Port allows data to be downloaded. EP-TECH computer software has the ability to graph and present saved data verses number of readings or distance. GPS Coordinates automatically will be saved for all reading. It is an easy way to map the pipeline by using ‘GPS option’.

 
Send Email

Soil Test Resistance Meter

Sophisticated electronic digital null meter, the Soil Test Resistance is using to measure soil resistively and determining optimum location for earth Electrodes and Anodes.

 
Send Email

Pipe And Cable Locator

Sophisticated Electronic Receiver is equipped with a search coil and able detect coated pipeline signal for a great long distance by using null method theory. Transmitter conductively connected to the pipe by a remote ground and equipped with Interruption mode to eliminate noise and stray currents. The Transmitter has different output levels to match the impedance to all soil conditions.

 
Send Email

Digital C.P Multimeter

This equipment is used for cathodic protection monitoring in the field. This voltmeter is protected against AC power lines or telluric stray current and suitable for potential survey DC and AC of the Pipeline Test Points.

 
Send Email

Digital Voltmeter

Tinker & Rasor Model CPV-4 Cathodic Protection Voltmeter is a revolutionary instrument for measuring DC structure-to-earth potentials of various buried or submerged metallic objects. Powered by an ordinary 9-volt battery, the Model CPV-4 gives an immediate reading in large ½ inch (12.7mm.) liquid crystal display numerals. 
The large scale integrated circuit has a built-in filter to reject AC interference. Input resistance of 11 megohms (11 million ohms) yields potentiometer quality voltage readings, and digital readout eliminates interpolation of voltages. This small, lightweight instrument needs no warm-up time, is insensitive to temperature, and can be read in direct sunlight. Low current CMOS circuitry assures long battery life, and the die-cast metal casemakes the CPV- 4 a durable instrument for the field.

 
Send Email

Copper Sulfate Portable Half Cell

Tinker & Rasor now offers a complete line of Copper - Copper Sulfate Reference Electrodes. Made of the most DURABLE PLASTICS, they will withstand severe abuse without damage. The Half Cells have a FULL VIEW WINDOW, which allows liquid level observation without removal of sealed ends..

The pre-saturated ceramic plugs are of a special design for LOWER EARTH RESISTANCE contact and also allow for easy probing in hard earth. These ceramic plugs provide a larger surface area than ever before.

 
Send Email

Cable And Pipe Locator

The TOMKAT 2 Cable Locator is a full function industry standard pipe and cable locator, designed and manufactured by Pact Services-UK.
Better in design, the TOMKAT 2 is rugged, lightweight and packed full of features including a detachable speaker that can be held close to the ear for use in noisy environments. 

 
Send Email

D.C.V.G Survey Equipment

Caltech Engineering Services- India offers basic and standard DCVG equipment.
DCVG-UK manufactured useful equipment. when DC is applied to a pipeline in the same manner as in cathodic protection, a voltage gradient is established in the ground due to the passage of current through the resistive soil to the bare steel exposed at a coating fault.

The voltage gradient becomes larger and more concentrated the greater the current flowing and the closer you are to a coating fault location. In general,  the larger the fault, the greater the current flow and hence bigger the voltage gradient.

The direct current voltage gradient method (DCVG) uses a sensitive mili-volt meter, to indicate the potential difference between two copper/copper sulphate half cells placed in the soil in the voltage gradient at ground level. If spaced two metres apart in a voltage gradient, one half cell will adopt a more positive potential than the other, which thus enables the size of the gradient and direction of the current flow causing the voltage gradient to be established.

 
Send Email

Soil Resistivity Meter

The Tinker & Rasor SR-2 Soil Resistivity Meter is a highly accurate and easy-to-use soil resistivity instrument for use with the 2-pin and 4-pin (Wenner) methods of soil resistance measurement. A pin selector switch allows choosing between 2-pin and 4-pin tests without removing cables.

Model SR-2 provides easy resistance readings with a digital 4-1/2 digit display, push-button operation, and an easily adjusted Ohm to MOhm range selector. The display will show in the correct range. Multiply reading with pin spacing multiplier for Ohm-cm.

Use the SR-2 to find soil resistivity for a variety of cathodic protections applications, including pipelines, tanks, wells, etc. Also use for geological and archeological studies.

 
Send Email

Insulator Tester

The Model CE-IT Insulator Tester is a fully automatic, highly sensitive, LCD readout device to test buried pipeline insulators and isolation of pipelines in road crossing casings to determine their effectiveness. It automatically adjusts to the voltage polarity present on underground pipeline systems in under 20 seconds. An audible signal is heard when the test cycle is completed. Equipped with a power switch, the unit automatically shuts off in 10 minutes to conserve batteries. It comes complete with six (6) "AA" batteries and two (2) needlepoint probes.

 
Send Email

Indentation Resistance Tester

Caltech Engineering Services offers Indentation Tester or Indentation Resistance Tester complies with ISO 21809 and DIN 30670 standards.

Indentation Tester or Indentation resistance tester is highly useful for testing of indentation hardness using penetrometer of polypropylene (PP) and polyethylene (PE) material at above ambient temperature upto 90°C or 120°C up to 6 samples at a time. Indentation Test is recommended as per ISO 21809-1:2011 / DIN 30670: 2012 standard.

Indentation resistance tester has indentation or penetrometer for punching in the coating under fixed conditions of temperature and load in liquid media such as water.

 
Send Email

Indentation Test Low Temperature

Caltech Engineering Services offers low temperature indentation bath, which is highly useful for testing of coating material at above ambient temperature upto -5 deg Cent. Uniform temperature is maintains in the bath, measured by electronic display on the control panel. Timer can be set to the required time to continuously run the test.

 
Send Email

Pearson Type Detector

The Model PD Detector and null Method have been well accepted by the industry. Acclaimed to be the fastest method known to accurately locate points of electrical contact and insulating joints on coated pipelines. This type survey may be conducted on coated pipelines regardless of their location. Unaffected by parallel lines, depths or cover, the survey can often be, in part, conducted from a moving vehicle over the pipe. In brief, the Null Method follows the flow of impressed audio frequency current in a coated pipe and determines where it leaves. The point of current discharge is determined by a sharp disturbance of the null itself rather than the signal level of the audio frequency. This method is quite practical, particularly as competent field personnel can interpret findings quickly and accurately.

 
Send Email

Oscillator

The oscillator provided with the set has been designed to use the latest developments in this type of instrumentation. A signal of 750 c.p.s. is generated by using a power transistor switching circuit. This arrangement eliminates troublesome vibrators, buzzers or other moving part elements. The Transistor Oscillator converts low voltage (twelve volts) d.c. to stable audio frequency a.c. directly and hence, by a highly efficient method, the input current to the Oscillator is only 1.7 amperes for a full output of fifteen watts, a conversion efficiency of better than 80%. In order that a maximum of energy can be transferred from the Oscillator to the pipe, the output of the oscillator is provided with taps so that voltages of 2.5. 5, 7.5, 15, 50, and 100 volts are available to match the load. An interrupter is provided to make the signal more easily recognized. 

 
Send Email

Silver Chloride Reference Cell

Silver Silver Chloride sea water / marine service reference cell is the regular immersion reference electrode to measure electrical potentials for corrosion engineers. It is used asr permanent fresh water service electrode. These electrodes has specialty to retain and quick drain of water to show uninterrupted and accurate results all the time. The silver / silver chloride reference electrode is a widely used reference electrode because it is simple, very stable and non-toxic. It is mainly used in seawate, river water and high water content soils, mudy water.

 
Send Email

P.R.M Peak Reading Meter

The Tinker & Rasor Model PRM Peak Reading Voltmeteris designed to measure the peak value of   high voltage DC pulses within its scale range, with a maximum capacity of 40 kilovolts Measurement   can be made of peak values with rise time of less than one microsecond.

 
Send Email

Polarization Cell

Polarization cell protects against induced AC current and ground fault current on buried pipelines. Polarisation cells permit low-level voltage of cathodic protection to uniform flow and prevent hazardous voltages. Polarization cell consist of multiple plates of steel arranged, fixed and immersed in 30% KOH (Potassium Hydroxide) solution. Specially selected oil layer stop the evaporation of solution to some extend. It is advisable to verify the solution level periodically. Polarization cell is fitted in transparent body to check solution level. Normal storage of cell does not have any internal voltage and act as a grounding switch in presence of high voltage. Polarisation cell works on electrochemical principle. Installed plates with large surface area polarize and allow in developing safe DC voltage suitable for cathodic protection. As the voltage increases from DC or AC voltage, the polarisation film breaks and polarization cell conduct current. Specially designed polarization cells have properties to retain solution level to the maximum period with specially added floating oil. Polarisation cells are designed to protect personnel and equipment from electrical disturbances

 
Send Email

Tinker And Rasor Portable Power Supply

The Tinker & Rasor portable power supply is an ideal DC current source for many cathodic protection corrosion maintenance tests. Weighting only 10 pounds, the CS-10 comes complete with batteries as well as accommodations for connecting to external power source.

Common usage is for determining current requirements for cathodic protection and impressing current on an underground structure for assisting in locating electrical contacts with foreign systems such as, foreign under ground utilities.

The CS-10 is sold complete with (9) batteries, charger, 12 Volt lighter adapter. The instrument also contains one 9 volt alkaline battery with life expectancy of 2 years or more. Pelican manufactures the instrument case. It is considered indestructible and is water resistant.

 
Send Email

Solid State Polarization Cell

Caltech Engineering Services- India introduces, Pa-El's Solid state polarization cell is semiconductor cell used for short-term current peaks and over voltage drainage. It is also used for synchronization of cathodic protection system with lightning strike protection demands for gas reduction station, measuring reduction station, blockade station etc.

 
Send Email

 
  CONTACT US AT
CALTECH ENGINEERING SERVICES
ADDRESS : D-104, Twin Arcade, Military Road, Marol
Andheri (E), Mumbai-400059 (Maharashtra)


Contact : ,

Send Email


Send Email

WEBSITE : www.goldenpages.in/caltechengineeringservices
Contact Person :


Mobile : Send SMS
 
Home | About Us | Products | Contact Us |
 
Copyrights @
Caltech Engineering Services
Site Designed & Maintained by Aman Infotech
 
 
Back to Top


About Us, Adjustable Fillet Weld Gauge, Analog Surface Profile Gauge, Automatic Weld Size Gauge, Bent Beam Test, Bresle Test Kit, Cable And Pipe Locator, Calibration Services, Cathodic Disbondment Test Equipment, Cathodic Protection Instruments And Equipments, Chlor Testa, Chloride Test Kit, Chloride Test Kitfor Water And Liquid, Coating Thickness Gauge, Coating Thickness Meter, Color Cards, Concrete Moisture Meter, Conical Mandrel Bend Tester, Copper Sulfate Portable Half Cell, Corrosion Coupons, Corrosion Pit Gauge, Corrosion Testing Instruments And Accessories, Cross Hatch Cutter Accessories, Cross Hatch Cutter Kit, Current Interrupter, D. C. V. G Survey Equipment, Dew Point Meter, Dewpoint Tester, Digital Adhesion Tester, Digital C. P Multimeter, Digital Pit Depth Gauge, Digital Surface Profile Gauge, Digital Thermometer, Digital Voltmeter, Dust Test Kit, Dustiness Tape, External Rolling Spring Electrodes, Fillet Weld Gauge, Fineness Of Grind Gauge, Four Point Bend S. S. C Test, G. P. S Pipeline Current Mapper, Gauss Meter, Gloss Meter, Grit And Shot Blasting Comparator, Hexagonal Wet Film Thickness Gauge, Hexlogger, Hi Lo Welding Gauge, Holiday Detector, Hydraulic Adhesion Tester, Hydrogen Induced Cracking Test, Hypodermic Needle Pressure Gauge, Indentation Resistance Tester, Indentation Test Low Temperature, Infrared Thermometer, Inspectin Services, Inspection Flashlight Torch, Insulator Tester, Intelligent Glossmeter, Internal Conductive Brushes, Jeep Meter, Magnetic Surface Thermometer, Multi Blade Cross Hatch Cutter Kit, Oscillator, Oval Inspection Mirror, P. C. B Copper Thickness Tester, P. R. M Peak Reading Meter, Paint Evaluation Tool, Paint Inspectors Kit, Paint Thickness Tester, Pearson Type Detector, Pencil Hardness Tester, Pinhole Detector, Pipe And Cable Locator, Pipe Pit Gauge, Pocket Telescopic Inspection Mirror, Polarization Cell, Portable Leeb Hardness Tester, Potassium Ferricyanide Test Kit, Pressure Blast Analyzer Gauge, Prosonic Ultrasonic Steel Thickness Gauge, Pull Off Adhesion Tester, Rapid Chloride Permeability Test Equipment, Rebar Corrosion Voltmeter, Root Weld Spacing Gauge, Rotary Abrasion Tester, S. S. C Proof Rings, S. S. C Temperature Pressure Vessels, Salt Spray Test Apparatus, Scratch Hardness Tester Manual, Silver Chloride Reference Cell, Socket Weld Contraction Rings, Soil Resistivity Meter, Soil Test Resistance Meter, Solid State Polarization Cell, Spring Loaded Roller, Testex Snap Gauge, Testex Tape, Tinker And Rasor Portable Power Supply, Tooke Paint Inspection Gauge, Ultrasonic Thickness Gauge Steel, Welding Inspection Flashlight Torch, Welding Inspection Mirrors, Welding Profile Gauge, Wet Film Thickness Gauge, Wet Film Wheel Gauge, Whirling Hygrometer